The Smart Air
It means we take the“innovative thinking” as the core driving force of enterprise development, to bring safer, more environmentally friendly & more energy-efficientsolutions for the global users, and promote the development of green spaces.
Smoke Ventilation Fans
![](https://ventum.ae/wp-content/uploads/2024/07/RPZ-fan_ventum_Series.jpg)
RPZ Series
- Hi-Temperature-Resistant Axial Fan.
- Suitable for smoke-extracting when for fire control.
- Adjustable angle for impeller: 8° to 36°.
- The gas dust content required not exceed 150mg/m3
- Using the thermostable electrical motor, the air blower can work at least 30 minutes in 280°C ambient temperature.
- Size: 400-1250mm, eleven different sizes.
- Air volume: 1000~80000 m3/h
- Total pressure: maximum to 1280 Pa
- Applications: the exhaust/ supply fans for high-rise buildings.
![](https://ventum.ae/wp-content/uploads/2024/07/Untitled-1-08-min.jpg)
PDFU Series
- Plug Fan with Cabinet.
- It is a cabinet fan developed on the basis of the PDF-R3.
- Adopt PDF-R3 series plug fan inside the cabinet. There are two types of transmission: type A and type C.
- The cabinet made of galvanized steel sheet, attractive & durable, with the function of noise insulation & reduction.
- Usage: ventilation for industrial and mining enterprises, high-rise buildings, hotels and shopping malls.
- Models: total l 5 models from the impeller diameter 250mm to 1250mm.
- Maximum air volume: 126700 m3/h
- Highest static pressure: 3580 Pa
![](https://ventum.ae/wp-content/uploads/2024/07/PDF-R3-Series-ventum.jpg)
PDF-R3 Series
- PDF-R3 Series Plug Fan.
- Upgraded version of PDF series with higher efficiency than old version.
- Backward curved non-volute ventilator, unconstrained air flow design, big pressure, and low noise.
- Motor direct drive, simple structure, easy installation.
- Used for variable air volume system or clean air conditioning system.
- Models: total 15 models from the impeller diameter 250mm to 1250mm.
- Maximum air volume: 126700 m3/h
- Highest static pressure: 3580 Pa
![](https://ventum.ae/wp-content/uploads/2024/07/TDF-A-R3-ventum.jpg)
TDF-A-R3 Series
- Single Inlet Centrifugal Fan
- Single inlet, backward impeller. motor-direct driven, simple structure. high efficiency. high static-pressure.
- Installation angle: 0° , 90° , 180° , 270° four angles for choose.
- Usage: ventilation or match for purifying equipment.
- Model: 315-710 eight sizes.
- Air volume: 532-26735 m3/h
- Total pressure: 107-5149 Pa
![](https://ventum.ae/wp-content/uploads/2024/07/TDF-SWC-R3-ventum.jpg)
TDF-SWC-R3 Series
- Single Inlet Centrifugal Fan
- In metric system, backward curved blade impeller, single inlet.
- C type belt-driving.
- Size: 315-1000mm, eleven different sizes.
- Air volume: maximum to 45000 m3/h
- Total pressure: maximum to 2770 Pa
![](https://ventum.ae/wp-content/uploads/2024/07/TD-SW-R3-ventum.jpg)
TD-SW-R3 Series
- Single Inlet Centrifugal Fan
- Belt-driving, backward curved blades impeller.
- In metric system, single inlet.
- Sizes: 200mm to 1000mm fifteen different sizes.
- Air volume: 400-45000 m3/h
- Total pressure: 2770 Pa
![](https://ventum.ae/wp-content/uploads/2024/07/TDF-C-GC-Series-ventum.jpg)
TDF-C-GC Series
- High Temperature Insert Fan.
- Single inlet, backward impeller.
- Size: 280-1000.
- High efficiency and high static pressure.
- C type, inserted structure, disassemble casing.
- Air cooled type, temperature of air must be below 280°C.
- Suitable for high temperature oven, kiln and high temperature air supply, hot air circulation equipemnt supporting.
- Air volume: 531 -45695 m3/h
- Total pressure: 140-2148 Pa
![](https://ventum.ae/wp-content/uploads/2024/07/TDF-AL-ventum.jpg)
TDF-AL Series
- TDF-AL Stand Type Purification Centrifugal Fan.
- Stand type centrifugal fan special for painting.
- Advanced structure and easy to maintain by turning over impeller without opening duct.
- Large air volume and high static pressure.
- Widely used in purifying painting or matched using with other equipments.
- Size: from 355 to 710mm.
- Air volume: up to 24449 m3/h
- .Total pressure: up to 3693 Pa
![](https://ventum.ae/wp-content/uploads/2024/07/TDF-R3-ventum.jpg)
TDF-R3 Series
- Backward Curved Centrifugal Fan.
- In metric system, backward curved and double inlet.
- High efficiency, low noise, belt-driving.
- Suit matching in central air-conditioner, purification equipment and so on.
- Type: D, K , HL, HM and GM five different types, & we have 250, 280, 315, 355, 400, 450, 500, 560,
630, 710, 800, 900, 1000, 1120, 1250 fifteen different sizes. - Air volume: 550-227500 m3/h
- Pressure: maximum to 3730 Pa
![](https://ventum.ae/wp-content/uploads/2024/07/TDFT-R3-ventum.jpg)
TDFT-R3 Series
- Backward Curved Purification Centrifugal Fan.
- Developed on the base of TDF backward curved cenrtrifugal fan,
double-inlet, easy application & installation. - Suit matching in central air-conditioner, purification equipment and so on.
- Type: we have 250, 280, 315, 355, 400, 450, 500, 560, 630, 710, 800, 900, l 000, l 120, 1250 total 15 different sizes.
- Air volume: 550-227500 m3/h
- Pressure: maximum to 3730 Pa
![](https://ventum.ae/wp-content/uploads/2024/07/TAE-ventum.jpg)
TAE Series
- Forward Curved Centrifugal Fan.
- Developed on the base of TDF backward curved cenrtrifugal fan,
double-inlet, easy application & installation. - Suit matching in central air-conditioner, purification equipment and so on.
- Type: we have 250, 280, 315, 355, 400, 450, 500, 560, 630, 710, 800, 900, l 000, l 120, 1250 total 15 different sizes.
- Air volume: 550-227500 m3/h
- Pressure: maximum to 3730 Pa